Installation
Note:
Installation will be better achieved with a crew of at least three. Before
attempting installation, be certain that all gas pressure to the wellhead is
shut off and secured.
Wellhead
Preparation:
1.
Shut in top
master valve and wing valve.
2. Shut needle valve in, bleed off excess pressure from
gauge and remove gauge.
3. After pressure is off remove BHTA(bottom
hole test adapter), cap, and disregard.
4. Install the 2 3/8" 8rd
(or thread size appropriate to your BHTA) nipple.
Note: Your Lightning Auto LoaderTM comes equipped with a
2 3/8" 8rd thread. Lighting Auto LoaderTM Installation:
1.
Install the
"A" assembly on nipple. Position and tighten
so that the 2"x16" Mount Nipple is facing opposite of the wing valve
and choke.
2.
Install large air cylinder by inserting the 1" nut and bolt, taking
care not to overtighten,
this will
successfully attach the air cylinder pending connection of the supply gas.
3.
Install the
boom section by inserting the rod pin in clevis and clip, then
insert
hinge pin into the lower funnel hinge and boom through the brass
bushings
and clip.
4.
Insert inner
tube into nut boom and hand tighten to hold in place. This will be further
adjusted later.
Linkage Installation:
Note: Linkages are factory
pre-adjusted.
·
Install pin in
clevis and clip.
·
Install
equalizer linkage pin and clip.
5.
Insert legs
into base and secure with leg bolts.
6. Pick up machine and move the back of the machine to
the boom section. Raise the "big foot" and place in the holder.
Installation
Continued
Leveling
the base and adjusting the boom:
·
Level base then tighten leg bolts.
·
Level bottom "big foot" lip even with, or slightly lower than bottom lip of soap
stick dispenser opening
·
Level foot holder flush against Big Foot
· Pull inner boom in or out,
adjusting "big foot" to position in holder, level, then tighten nut.
Note: Big foot must be even with dispenser as described or soap stick will not dispense properly
Connection of supply gas and air
cylinder:
Note:
Best results are achieved by using a good. dry, gas supply.
·
Attach supply gas line to collar marked "Supply In".
·
Connect black tubing to collar marked "Out" and to the bottom
of the large cylinder. Leave a
'A coil length
when attaching hose to cylinder as to allow for movement.
Post Installation Testing:
It is advisable to test your Lightning
Auto LoaderTM after
assembly to ensure proper operation.
1.
Turn off the controller.
2.
Load rack with soap sticks.
3.
Turn gas supply on.
4.
Turn controller on.
5.
Press exit button.
6.
Press "Drop".
Caution: Machine will now activate. Also note that controller
is now in
duration time of 120
seconds. At the end of this time the boom will return
to its down position.
With testing now completed, set
the controller. For this step, refer to the controller manual.
CONTROLLER
INSTRUCTION MANUAL
Welcome to the controller instruction
manual. In this section you will learn how to program and activate the computer controller for
your Lightning Auto Loader.
You will begin by setting the clock to the correct time and
day:
· Press the exit key,
this will activate the display panel.
· Press the mode key
to make the day selection blink
·
Set
the day by using the up or down buttons
·
Once the day has been set, press the mode key
to make the hour selection
blink.
· Set the correct hour with the up or down keys.
● Be certain to scroll through to set the time
for either AM or PM
● Press the mode button and
follow the same procedure to set the
minutes
·
After the correct time and day have been set,
press the exit key to save your
settings
CONTROLLER INSTRUCTION MANUAL CONTINUED
Now that your clock has been set to the correct
time and day, you may proceed to the next
step: setting the soap drop times.
·
Press the exit key to
activate the display panel
·
Next press the mode key then
the drop key
·
You are now in the soap drop
menu. By using the up and down keys, set the day that you wish to drop
soap.
·
Press the mode key to
activate the hour selection. Use the up and down keys to set the hour that you
would want to drop soap.
·
Be certain to scroll through
to set the time for either AM or PM
·
After you have set the hour,
follow the same procedure to set the minutes
·
Once you have set the
minutes, press the mode key once again. This will show the selection "drop
on or off'
·
To set, use the up key for
on, or the down key for off
·
If you wish to drop another
stick on the same day. press the drop
key and repeat the steps to set
the soap drop time and day, press the exit key to save your settings.
·
Note: At the top of the
display you will find a counter indicating how many sticks you are dropping
during the week
·
After you have set all of
your drop days and times, press the exit key to save your settings.
·
For manual drop:
press exit then press drop
You
may at any point during these programming steps press the exit key to start
over.
Dislodging a lodged soap stick:
Caution: Saftey protection such
as hard hat, eye protection, and hearing protection must be worn at all times
during this procedure.
Step 1: Turn the dial on
the check valve to the "L.O." (lockout)
position, then pull the 3/8th pin in the ball valve handle.
Step 2: Open the ball
valve by pushing the handle upward.
Note: Caution should be taken
at this time due to the lodged soapstick ejecting at
high velocity.
Step 3: After soapstick has been dislodged and ejected, replace red pin
in ball valve handle and turn dial to "Auto". Now your machine is
back in automatic.
TROUBLESHOOTING AND MAINTENANCE
Cleaning and lubrication:
The Big Foot and the slider rack may be
washed with plain warm water. More stubborn soap build-up can be removed with
the use of a household Soap scum remover.
Please note,
the Lightning Auto Loader requires no lubrication of any kind.
Troubleshooting:
Although your Lighting Auto
Loader is designed to deliver virtually trouble-free operation, we have
provided solutions to some more common problems.
Boom remains in
upright position:
-System is over-pressured, replace or adjust
regulator
-Solenoid may contain debris, clean out solenoid
No display on LCD
controller screen:
-Check, or replace batteries
Leaking Ball Valve:
-Adjust
linkage